Reminder: RMSSD and SD1 are identical heart rate variability metrics
- Anthony B. Ciccone,
- Jacob A. Siedlik,
- Jill M. Wecht,
- ,
- Nhuquynh D. Nguyen,
- Joseph P. Weir(corresponding author)
- University of Kansas,
- Creighton University,
- VA Medical Center,
- the Icahn School of Medicine,
- Osness Human Performance Laboratories
Abstract
Assessment of heart rate variability (HRV) is a common approach to examine cardiac autonomic nervous system modulation that has been employed in a variety of settings. Frequently, both the root mean square of successive differences (RMSSD) and SD1, which is a Poincaré plot component, have been used to quantify short-term heart rate variability. It is not typically appreciated, however, that RMSSD and SD1 are identical metrics of HRV. As a reminder to clinicians and researchers who use and study HRV, we show both empirically and mathematically that RMSSD and SD1 are identical metrics. Because the homology between RMSSD and SD1 is not commonly known, the inclusion of both measures has been reported in many recent publications. The inappropriate use of such redundant data may affect the interpretation of HRV studies. Muscle Nerve 56: 674–678, 2017.
Bibliographic Information
Output type
Original language
EnglishPages from-to (Number of pages)
Pages 674-678 (5 pages)Journal (Volume, Issue Number)
Muscle and Nerve (Volume 56, Issue 4)Publication milestones
- Published - 10/2017
Publication status
ISSN
0148-639XPublication IDs
- Scopus: 85017581388
- PubMed: 28073153